Modern electrician in the house or apartmentrepresents a wide variety of technical means requiring control over the supply of voltage. Power management produces a three-phase voltage relay, a closing or opening electrical circuit in the event of an emergency.
Most protective devices containcontrol electronic relays. If the monitored parameters are deflected beyond the preset limits, they are triggered by disconnecting the circuits. All relays consist of three elements. The first of them is perceiving. It transfers the value of the monitored value to the intermediate element, where it is reconciled with the normative indicators. With deviations, the signal is transmitted to the executive device, which turns off the power.
Power surges in the supply of electricity, andAlso, interruptions in the power supply circuit can cause the failure of consumer devices. In worn-out electrical networks, there may be phase coalescence or zero wire firing, which leads to voltage distortions from 0 to 380 V. All connected household electrical appliances that do not have protection can be damaged.
The three-phase voltage relay serves toinstantly respond to an increase in voltage above the permissible and open the electrical circuit. The phase is turned off when a magnetic flux occurs in the electromagnet as it passes through the current winding. With the help of an electronic circuit, the relay is adjusted to certain voltage limits, when exceeding, the electrical contacts in the load circuit open.
The voltage relay is installed in the roomelectric board, but there are models that plug into the outlet. With their help, the lower and upper limits of the voltage change are selected. It is convenient to set the range of 180-245 V, and then additionally adjust so that the number of trips is no more than one per month. When the voltage in the network is constantly high or low, it is advisable to install a stabilizer.
The connection of the three-phase voltage relay must be done after the input automaton, the nominal value of which is selected one step less, for example, in a ratio of 32 A and 40 A.
The three-phase voltage relay is connected tocurrent-carrying and neutral wires of the network, as well as to the load connection output terminals for monitoring their condition. Changing the modes is done by switching jumpers on the relay terminals. When activated, the coil de-energizes and opens the power contacts. With them, the winding of the power contactor can be connected, which also works, disconnecting the consumers. Through the time delay, when the voltage is restored again, the relay returns to its original state, closing its power contacts.
The above scheme disconnects consumers fromthe occurrence of a problem on the network. Protection can also be built on 3 single-phase independent voltage relays. It is used at separate loads for each conductive conductor wire. Power contactors are not normally used here, if the load is not more than 7 kW. The advantage of the method is to keep the voltage on the remaining phases when one of them is switched off.
The devices differ among themselves in functions andquality. Depending on whom, for what purposes you need such devices, they are selected and installed. Next, consider the most popular devices.
The device protects the network during the following accidents:
The device also monitors other network parameters and disconnects the load power when they deviate from the norm. Three-phase voltage relay RNPP-311 can be tuned to two monitoring modes.
On the front panel there are indicators of the presence of voltage, load connection and some abnormalities. The adjustment is made by six potentiometers. The following parameters are set:
The device remains operable when zero and one of the phases remain active or at least two.
The device serves for the following monitoring methods:
The thresholds are set by two potentiometers. The display allows monitoring of voltage, network faults and activation of the built-in electromagnetic relay. Operating conditions are normal.
Wiring plan for three-phase voltage relayRKN-3-15-08 practically does not differ from the one given earlier. It only has a simpler setup. At this voltage relay three-phase price is slightly lower than at RNPP-311. It is about 1500 rubles. Different modifications of both types can significantly differ in cost, it all depends on the functionality.
In a separate series there are fully digitalprotective relay series ASP. Most of them no longer find tuning elements for analog signals. Potentiometers depend on the influence of the external environment, quickly age, the values change, and contact often disappears.
Digital devices do not contain contactmechanical parts, due to which the effect of external factors is reduced, and their reliability increases. In appearance, the devices are characterized by a digital display. The price they have on average higher, but you can find a budget position.
The model is basic, and it has all thenecessary functions, which must have a three-phase voltage relay. Its price is 2 times lower than other devices with built-in digital voltmeters and screens. If no display is required, and protection is needed, the device is perfectly suitable for installation.
Three-phase voltage and phase control relay withmicroprocessor is used to control the supply of electricity to refrigerators, air conditioners, compressors and other devices where electric motors are used. The device is convenient in that it allows you to monitor the voltage at each phase of the display, as well as monitor its asymmetry. Built-in memory with power from an independent source makes it possible to memorize the parameters and the number of emergency trips with the ability to display. This does not require special skills for customization. Additional functions are available via the control buttons.
The ASP-3RVN device is connected to the network in parallelload similar to the schemes presented earlier. The device monitors the operating voltage of the network. In the event of an accident, it opens its contacts, which are included in the breakage of the starter winding. After connection and power supply, the protection relay checks the presence of voltage. This is signaled by three LEDs. If the sequence is interrupted or the phases stick together, dashes (-) appear on the indicator. Further, the measured phase voltages are displayed on the screen with an interval of several seconds. The corresponding LEDs light up.
In case of an accident, the screen displays the reasons for itoccurrence. The settings are first factory settings, but they can be changed by pressing the corresponding buttons. If errors occur during the installation, they can be reset and reset to factory defaults with a single click. All settings are stored in memory and can be checked.
One of the known devices for protectionElectrical equipment is a three-phase voltage relay ABB. The device has established itself as one of the most reliable in the violation of voltage balance. For three-phase networks, the ABB SQZ3 device has been designed to withstand a voltage of up to 400 V. A large assortment allows choosing a suitable model for certain operating conditions. The device allows you to monitor: